Monitor run
Private previewComposable dashboards and the metrics API are in private preview: available to invited accounts, and features may change. See Integration and feature lifecycles for what this means, and reach out to your account representative to request access.
Overview
A run of a monitor: one point on its chart. Group by it to get one row per run.
Used by the metrics of: Monitor runs
Dimensions
Group by or filter on these names; all dimensions: Dimensions.
| Dimension | Description |
|---|---|
monitor_run_item__is_anomaly | The run raised an alert: an anomaly on a learned (ML) threshold, or an alerted breach on a set threshold. |
monitor_run_item__is_collection_failure | The collection of the point failed. |
monitor_run_item__is_gapfilled | Point filled in for a missing collection; not a real run. In the product: shown on the monitor chart. |
monitor_run_item__is_marked_as_normal | A user marked the point as normal. |
monitor_run_item__is_monitor_run_item_breach | Point broke the static threshold of a MANUAL series; NULL for AUTO series (use monitor_run_item__is_anomaly) and for series without a threshold. Breach: a monitor run whose value broke the threshold condition (outside or inside a range, equal or not equal). In the API: monitor_run_item__is_monitor_run_item_breach, monitor_run_item_breach_count. |
monitor_run_item__is_within_maintenance_window | The point falls in a maintenance window of the monitor. |
monitor_run_item__monitor_run_item_lower_threshold | Lower bound of the run: the threshold band the monitor computed for the run, else the configured bound of a MANUAL series (threshold of LT / LTE, lower bound of a range). NULL otherwise. |
monitor_run_item__monitor_run_item_measured_at | When the point was measured (UTC, to the second). |
monitor_run_item__monitor_run_item_outcome | breach / pass against the operator and the lower / upper threshold of that run (EQ / NEQ against parent_time_series__parent_time_series_threshold); anomaly / no_anomaly from the detector for AUTO series; track for NOOP and for series without an alert condition (operator_type NONE); unknown on a set threshold when there is no value or no threshold (relative and percentage thresholds are always unknown). |
monitor_run_item__monitor_run_item_upper_threshold | Upper bound of the run: the threshold band the monitor computed for the run, else the configured bound of a MANUAL series (threshold of GT / GTE, upper bound of a range). NULL otherwise. |
monitor_run_item__monitor_run_item_value | Value measured by the run. |
Updated 4 days ago
Did this page help you?